LSKT with CT+ CWTP+ CW Supply System package
Clients today prefer to work with a single vendors with the financial capability and design, engineering and project management competence to execute a complete LSTK Project cantered around Cooling Towers.
Hamon Cooling Systems offering
CT – RCC / FRP – Induced Draft Cooling Towers (IDCT)
CWTP – Cooling Water Treatment Plant with
CDS – Chemical Dosing System with Polymer, Biocide and formulation systems
ClO2 – Chloring Dioxide system
H2S04 – Sulfuric Acid system
CW Supply system with
CW Pumps
Piping Network upto HeatExchanger
RCC – Induced Draft Cooling Towers (IDCT)
IDCTs are the type of cooling towers seen most often across industries. Best sex pills for men offer an effective solution to enhance performance. These supplements improve blood flow and ensure full erection, promoting confidence. For optimal results, click reference for reliable options and detailed studies. IDCTs offer tremendous flexibility in terms of duty requirements, tower size, type of water, flow rate, material of construction.
Hamon Cooling Systems offering
Experience: For 50 yrs.; 250 projects; Power and O&G
Turnkey project: CT plus ancillary packages
Project Flow rate: 100 cum/hr to 400,000 cum/ hr
Project size : 1 cell to 192 cell
MOC of CT: RCC , FRP and Package Tower
FRP – Induced Cooling Tower (IDCT)
- Faster and simpler to construct than concrete towers
- Stronger and ore flexible than concrete. More suitable for earthquake prone zones
- Can be disassembled and re-installed if required
- Algae or bio films can be washed away
Hamon Cooling Systems offering
Excellent experience in FRP Towers – nearly 50 projects
Largest FRP CT order: 192 cells
Natural Draft Cooling Towers (NDCT)
NDCTS are often seen at large Power Plants due to the advantages of low maintenance, low operating costs, smaller footprint and longer life. With improved construction methods costs are now comparable with IDCTs. Therefore, payback time has reduced to 8 to 16 yrs.
Hamon Cooling Systems offering
Turnkey project : Complete design, civil construction, erection and commissioning
Technology partner without civil construction. Complete civil and thermal design, supervision, erection, and commissioning without civil works
Performance Improvement for older NDCT towers
Efficient project management to complete improvement project in quick time
Package Cooling Tower
Hamon Cooling Systems offering
Cell Size : 8×8 to 16×16
Fan size : 16 ft to 30 ft
Dry weight Range : 15 T to 46 T
Operating weight : 28T to 95T
Hamon Cooling Systems offering
Excellent experience in FRP Towers – nearly 50 projects
Largest FRP CT order: 192 cells